What the law requires

RuleApplies toMinimum
Spanish RDL 29/2021, art. 4
Since 2023
Existing buildings with more than 20 spaces1 per 40 spaces or fraction (up to 1,000; then 1 more per 100)
Spanish CTE DB-HE 6
Works from Dec 2022
New buildings and works, with more than 10 spaces1 per 40 spaces or fraction and ducting for 20 %
German GEIG
Until 2026
New with more than 6 spaces, works with more than 10, existing with more than 201 point and ducting for every third (new) or fifth (works) space; existing: 1 point
German GEIG
From 1 Jan 2027
New and works with more than 5 spaces; existing with more than 201 per 5 spaces (offices: 1 per 2) and pre-cabling for 50 %; existing: 1 per 10 or ducting for 50 %
French CCH, L113-13
Since 2025
Non-residential buildings with more than 20 spaces1 point and 1 more per 20 additional spaces
French CCH, L113-12New and majorly renovated, with more than 10 spaces1 point (2 above 200 spaces) and ducting for 1 space in 5
Dutch Bbl, art. 4.160b
Since 29 May 2026
New and majorly renovated, with more than 5 spaces1 per 5 spaces (offices: 1 per 2) and pre-cabling for half
Dutch Bbl
From 1 Jan 2027
Existing with more than 20 spaces1 per 10 spaces or ducting for half
Finnish Act 733/2020, §§ 5–7New and majorly renovated with more than 10 spaces; existing with more than 20New: 1–3 points by band and readiness for 20–50 %; existing: 1 point
Danish BEK 181/2020New and majorly renovated with more than 10 spaces; existing with more than 201 point and ducting for 1 space in 5; existing: 1 point
Swedish BFS 2026:4
Permits from 1 Jul 2026
New and renovated with more than 5 spaces; existing with more than 201 per 5 spaces (offices: 1 per 2) and cabling for half; existing: 1 point and, from 2027, 1 per 10 or ducting for half
Irish S.I. 393/2021, reg. 5New and majorly renovated with more than 10 spaces; existing with more than 201 point and ducting for 1 space in 5; existing: 1 point (since 2025)
Hungarian ÉKM decree 9/2023, §§ 4 and 10New and majorly renovated with more than 10 spaces; existing with more than 201 point and ducting for 1 space in 5; existing: 1 point (since 2025)
Slovak Act 555/2005, § 8a
Until 31 Dec 2026
New and majorly renovated with more than 10 spaces; existing with more than 201 station and ducting for 1 space in 5; existing: 1 station
Slovak Act 246/2026
From 1 Jan 2027
New and majorly renovated with more than 5 spaces; existing with more than 201 per 5 spaces (administrative buildings: 1 per 2) and cabling for 50 %; existing: 1 per 10 or ducting for 50 %
Czech Decree 146/2024, § 61
Since 1 Jul 2026
New and majorly renovated with more than 5 spaces1 per 5 spaces (offices: 1 per 2) and cabling for 50 %
Czech Decree 146/2024, § 61a
Due by 1 Jan 2027
Existing with more than 20 spaces1 per 10 spaces or ducting for 50 %
Croatian Act on energy efficiency of buildings, arts. 48–50
Since 1 Jan 2026
New and majorly renovated with more than 10 spaces; existing with more than 201 point and ducting for 1 space in 5; existing: 1 point
Latvian LBN 200-21, point 130.6 ff.
Since 1 Aug 2026
New and majorly renovated with more than 5 spaces1 per 5 spaces (offices: 1 per 2) and pre-cabling for 50 %
Latvian MK 730, point 12
Due by 1 Jan 2027
Existing with more than 20 spaces1 per 10 spaces or ducting for 50 %
Slovenian ZURE, art. 29New and majorly renovated with more than 10 spaces; existing with more than 201 point and ducting for 1 space in 5; existing: 1 point and ducting for 1 in 10
Estonian Building Code, § 65¹New with more than 10 spaces; non-residential with more than 201 point and ducting for every fifth space; above 20 spaces: 1 point
Lithuanian STR 2.06.04:2014, point 107¹
Since 2 Jun 2026
New, rebuilt and renovated non-residential buildings with more than 5 spaces1 per 5 spaces (administrative buildings: 1 per 2) and pre-cabling for 50 %
Lithuanian STR 2.06.04:2014, point 107⁴
Since 2 Jun 2026
Existing non-residential buildings with more than 20 spaces1 per 10 spaces or ducting for 50 %
Romanian Law 372/2005, art. 15(1)New and majorly renovated non-residential buildings with more than 10 spaces1 point and built-in ducting for 20 % of the spaces
Romanian Law 372/2005, art. 15(2)
Since 1 Jan 2025
Existing non-residential buildings with more than 20 spacesPoints for 10 % of the spaces, at least 2
Bulgarian Ordinance RD-02-20-2, art. 50(2)–(5)
Since 1 Jan 2019
New and reconstructed public-service and mixed-use buildings with more than 10 spaces2 points (over 22 kW and up to 3.7 kW) and ducting for 1 space in 5
Bulgarian Ordinance RD-02-20-2, § 35
Since 1 Jan 2025
The same buildings with more than 20 spaces2 points (over 22 kW and up to 3.7 kW)
Portuguese Portaria 138-I/2021, 8.1(c)New or majorly renovated commerce and services buildings2 charging points and ducting for 1 space in 5
Portuguese DL 101-D/2020, art. 14(2)
Since 31 Dec 2024
Existing commerce and services buildings with more than 20 spaces2 charging points
Polish e-mobility act, art. 12aNew and majorly renovated, with more than 10 spaces1 charging point and ducting for 1 space in 5
Italian DM 28/10/2025, Table 5
Permits from 3 Jun 2026
New and majorly renovated with more than 10 spaces (private car park)3 points (2 in renovations) with 11–20 spaces, 3 per 20 up to 100 and 3 per 50 above; ducting for 1 space in 5
Italian DM, existing buildings
50 % from 2025, 100 % from 2030
Existing with more than 20 spacesThe same table as a new building
EU Directive, art. 14(1)
Transposition: May 2026
New or majorly renovated buildings, with more than 5 spaces1 per 5 spaces (offices: 1 per 2) and pre-cabling for 50 %
EU Directive, art. 14(2)
From 1 Jan 2027
All buildings with more than 20 spaces1 per 10 spaces or ducting for 50 %

For State General Administration buildings, Spanish law asks for 1 per 20 spaces.

A directive binds Member States until it is transposed. As of 28 October 2026 we have not found a Spanish rule transposing its article 14, so the calculator marks it as “pending in Spain”. Check the official gazette (BOE).

Exemptions

  • Buildings protected for their architectural or historic value, if compliance would alter their character.
  • Germany: SMEs that own and mostly use their building are exempt (§ 1(2) GEIG). The 2027 reform does not change this.
  • Finland exempts micro-enterprises that own and use their building; Denmark, SMEs that use their existing building; Sweden, non-profit organisations that are SMEs (the 2025 rule only).
  • Portugal: certified SMEs that own and occupy the building are exempt (only from the existing-building rule), as are industrial buildings, places of worship, warehouses, unconditioned car parks and listed buildings; a major renovation may be exempt if the cost exceeds 7 %.
  • Poland: buildings owned by SMEs are exempt. We found no duty for existing buildings without works in that act.
  • Ireland: buildings owned and occupied by SMEs are exempt. Hungary, Slovakia and Czechia have no SME exemption; a major renovation may be exempt if the cost exceeds 7 % (Slovakia, until 2026) or 10 % (Slovakia from 2027, Czechia).
  • Croatia: buildings owned or used by SMEs are exempt, and a major renovation if the cost exceeds 7 %. Slovenia: buildings owned by small enterprises, or not connected to the grid, are exempt. Latvia: a major renovation may be exempt above 10 %. Estonia: the text has no exemption.
  • Lithuania: no SME exemption; a renovation may be exempt above 10 % of its cost, and buildings whose energy-performance works were completed between May 2022 and May 2024 are exempt from the existing-building rule until 2029.
  • Romania: buildings owned and occupied by SMEs are exempt; a major renovation is exempt if the charging installations cost more than 7 % of it; public buildings with comparable requirements under Law 34/2017 and works whose building-permit application was filed by 10 March 2021 are also exempt.
  • Bulgaria: no SME exemption; for a reconstruction, renovation or major repair the duty may be skipped if the charging costs more than 7 % of the works.
  • Italy: SMEs that own and use their building, public buildings that already meet comparable requirements, renovations where the cost exceeds 7 % and isolated grids are exempt.
  • France: the number of points is capped if adapting the grid needs disproportionate works. Netherlands: for a major renovation it does not apply if the cost exceeds 10 % of the works.
  • CTE: does not apply with 10 spaces or fewer. For existing buildings with 20 or fewer, waived if compliance costs over 7 % of the works.
  • Directive: countries may exempt when the cost exceeds 10 % of a major renovation. Public buildings must have pre-cabling for 50 % of spaces by 2033.
  • The Directive also requires bicycle parking. This calculator does not cover it.

Frequently asked questions

How many EV charging points must a company car park have in Spain?

For an existing building with more than 20 spaces, one charging station per 40 spaces or fraction (RDL 29/2021). For new buildings and works, the CTE adds ducting for 20 % of the spaces. For State General Administration buildings, one per 20 spaces.

Since when is it mandatory?

RDL 29/2021 since 1 January 2023, and the CTE for building licences from December 2022. The EU Directive sets 1 January 2027 for existing buildings with more than 20 spaces, once each country transposes it.

What does the EU Directive require for an office car park?

Existing with more than 20 spaces: one point per 10 spaces or ducting for 50 %, by 2027. New or majorly renovated with more than 5 spaces: one point per 2 spaces (per 5 for other uses) and pre-cabling for 50 %.

What are ducting and pre-cabling?

Ducting is the conduits for cables that let you install chargers later. Pre-cabling also includes the cables, their routes and, where needed, the meters.

What if my car park has 20 spaces or fewer?

RDL 29/2021 does not apply. The CTE applies to new buildings or works from 11 spaces, and the Directive to new or majorly renovated buildings from 6.

Can the chargers be shared?

Yes. The rules set how many there are, not how they are used. With one-hour booking slots, a 7.4 kW charger serves 4 to 6 drivers a day.